Eleven failures that repeat in theatres, halls, stadiums and schools.

Most of them are details, not a ‘weak product’. Reading them before the pour saves the repeat measurement.

Reception and culture — auditorium and hall chairs by BOXTECH

The list

Each line is a failure seen on ordinary projects, not a client story pinned to a named building. The repair sits beside the line.

  • A wall that stops at the suspended ceiling. Repair: close the void to the slab at the same order as the wall.
  • A continuous screed under the partition. Repair: a cut, or a wall from the structural slab.
  • A door with no threshold. Repair: a complete set, not a heavier leaf.
  • Back-to-back electrical boxes. Repair: offset them and use a dense plug.
  • A shared duct between two classrooms. Repair: a silencer or an independent branch.
  • An operable wall under an open ceiling. Repair: a barrier above the track and a field measurement.
  • Suite glass with vent slots in the frame. Repair: close the frame, or a unit without slots.
  • An absorbing ceiling bought for a neighbour’s complaint. Repair: a separate insulation line; the absorber is only for the tail.
  • A gym over a classroom with a carpet. Repair: a floating floor or a resilient ceiling.
  • A rooftop generator with no resilient base and no silencer. Repair: mass, a door, silencers, and a mount on the machine’s frequency.
  • A measurement with the air system off. Repair: measure again at the agreed speed.