RT60 changes with frequency, volume, and use. One number for a hall type is a discussion target only. Sabine fails when absorption is high, and ISO 3382-1 is the measurement reference, not this page.

RT60 is the time for energy to fall 60 dB after the source stops, and it is not one number for the hall. A serious measurement reads it in bands, and T20 or T30 are extrapolated because noise hides the full fall. ISO 3382-1 describes that for performance spaces.

Definition

The definition ties the time to a fall, not to the operating level. A speech room and an unamplified music room of the same volume are not discussed with the same tail: speech wants the syllable to die, and music may want the energy to remain. This page sets no universal target in seconds for any hall type. A mid-band figure opened in a meeting is a discussion target until the brief and the measurement fix it.

The metric Sabine equation RT = 0.161 V / A ties the time to volume V and to total absorption A. The picture is sound: a larger volume lengthens the time if absorption per square metre stays put. The formula assumes a diffuse field and modest, distributed absorption. When panels cover a large area, or absorber gathers in the ceiling, it drifts from measurement. Eyring handles a higher mean and is still not the room.

Common mistakes

One second for the whole project — A lecture, a sports hall, and music do not share a target. One figure deletes use and volume.

Sabine after dense coverage — The formula is used where its assumption is weak, then the team is surprised by measurement. The formula’s limit is written with the result.

Reading only the mid band — The bass stays long and speech sounds coloured despite a neat mid-band figure.

Mixing RT60 with STI — A shorter time does not guarantee understanding if noise is high. The index is in IEC 60268-16.

When needed

Where used

Parts

Engineering

Materials

Related systems

Questions

Is there a correct value for every theatre?

No. Volume and programme change the discussion. This page rejects a universal target. The brief writes the band curve.

Why not trust Sabine?

Because it assumes low, distributed absorption. A hall covered in panels breaks the assumption. Measurement shows the gap.

Is T30 the same as RT60?

T30 estimates the full fall from part of the curve, inside the standard’s method. The report names the symbol. Do not mix the result with a Sabine calculation without saying so.

Is the calculator on the site enough?

No. It applies the formula to numbers you type. Replace the coefficients with laboratory reports, then with an ISO 3382-1 measurement.

Does a short RT60 mean a high STI?

Not always. Noise lowers the index. STI is in IEC 60268-16. The time is part of the story.